Well Pressure Switch Problems

The small gray box on the pipe near your pressure tank tells the pump when to run. When it acts up, you lose water or the pump never rests.

Quick answer: The pressure switch turns the well pump on at the cut-in pressure and off at the cut-out pressure, for example 30/50 or 40/60 psi. Common problems are no water (power off, burned or blocked contacts, a plugged sensing line, or a low well), a pump that won't shut off (leaks, worn pump, settings too high), and rapid cycling or chattering (usually a waterlogged or undercharged pressure tank). The tank's air charge should be 2 psi below the cut-in pressure. The switch carries line voltage, so turn off the power before opening the cover, and leave repairs to a qualified pro.

On most private well systems, the pressure switch is a small box mounted on a short pipe near the pressure tank, often next to a pressure gauge. Inside are two springs, a diaphragm that senses water pressure, and electrical contacts that switch the pump on and off. It's a simple part, but when it fails the symptoms can look like a bad pump, a bad tank or a dry well. This guide explains how it works and how a pro narrows it down. For a broader look at weak water, see well water pressure problems.

How the switch works

When you open a faucet, water flows out of the pressure tank and pressure falls. At the cut-in pressure the switch closes its contacts and the pump starts. The pump refills the tank, compressing the air inside, until pressure reaches the cut-out setting and the switch opens the contacts. The difference between the two is the differential. Schneider Electric's data bulletin for its Square D 9013F and 9013G switches uses 20-40, 30-50 and 40-60 psi as example settings.

The switch and the tank work as a pair. The Washington State Department of Health's pressure tank guide says the tank's air charge should be 2 psi below the pump's start pressure, and Schneider says the same: when instructions aren't available, set the bladder air pressure 2 psi below the cut-in pressure, measured with the tank drained. A 40/60 switch, for example, goes with a tank charged to about 38 psi.

Safety first

The switch is wired to the pump circuit and carries line voltage. Schneider's maintenance steps start with "Disconnect the power" before removing the cover. Its troubleshooting table is labeled as procedures for qualified service personnel. Reading the gauge and listening to the pump are fine for homeowners. Opening the switch and adjusting it is work for someone who knows electrical safety.

Symptom: no water, pump won't start

Schneider's troubleshooting table lists these causes when there's no water in the system:

If the pump runs but no water comes, or the pump hums and trips the breaker, the problem is likely the pump or well, not the switch. See no water emergencies and signs your well pump is failing.

No water, or the pump won't shut off?

Call (845) 524-9364 with your town and what the gauge is doing. A local well pro confirms availability.

Symptom: rapid cycling or chattering

If the pump clicks on and off every few seconds while water runs, or kicks on every time you use any water, the switch is usually reacting to a tank problem. Schneider's table lists a waterlogged tank and incorrect bladder air pressure for both rapid cycling and contact chatter. The Washington DOH guide describes the waterlogged tank signs: the pump motor cycles on and off rapidly, the tank sounds different when tapped, and water comes out when you press the pin of the air valve on top. It says waterlogged tanks should be replaced, and that bladder tanks last 5 to 7 years on average.

Other causes in the bulletin: an undersized tank, vibration if the switch is mounted on rigid pipe, and a faulty check valve that lets water flow back into the well. Rapid cycling wears out the pump. The Washington DOH warns excessive cycling may shorten the life of the pump motor. See pressure tank replacement.

Symptom: pump won't shut off

A pump that runs and runs means pressure never reaches cut-out. Schneider lists:

A pump that never stops can overheat and burn out, and a low-yield well can be pumped dry. If you can't find a reason, turn off the pump breaker and call for service.

Symptom: wrong pressure

If the pump turns on and off but at the wrong pressures, the bulletin lists incorrect settings, a defective pressure gauge, or a damaged diaphragm. Test the gauge before trusting it. A switch that can't be adjusted to the desired range should be replaced with one that has the correct range.

How a pro adjusts the switch

For reference, here is the general method in Schneider's bulletin for its switches. Follow your switch's own instructions.

  1. Turn off power, drain the tank, and set the tank air to 2 psi below the new cut-in pressure.
  2. Turning the main range nut raises or lowers cut-in and cut-out together. Raising cut-in by 10 psi also raises cut-out by 10 psi.
  3. Turning the differential nut changes only the cut-out.
  4. Restore power, run water until the pump starts, then watch the gauge to confirm the new on and off points.

Don't raise the settings past what your switch, tank and pump are rated for. Because the switch and tank work as a pair, a pro will usually check both.

Routine checks

Schneider recommends checking the switch during routine maintenance: no leaks at the diaphragm, no corrosion, no white mineral residue at the fittings, no frayed wires, and no insects. Keep the area dry and clear.

Related guides: sediment filters and low pressure, well pump repair and submersible vs. jet pumps.

Sources

Questions

What should my well pressure switch be set to?

Common settings are 30/50 or 40/60 psi. Whatever the setting, the pressure tank's air charge should be about 2 psi below the cut-in pressure, measured with the tank drained.

Why does my well pump turn on and off rapidly?

Usually a waterlogged or undercharged pressure tank. Other causes include an undersized tank, a faulty check valve or a switch on vibrating pipe.

Why won't my well pump turn on?

Check the breaker first. Then it may be burned contacts, a plugged sensing line under the switch, a low-pressure cutout that tripped because the well is low, or a pump problem. Have a pro diagnose it.

Can I fix a pressure switch myself?

Reading the gauge and checking the breaker are fine. The switch carries line voltage, and the manufacturer's procedures are written for qualified service personnel, so call a pro for repairs.

How do I know if it is the switch or the pressure tank?

Rapid cycling usually points to the tank. Check the tank's air valve: if water comes out, the bladder has failed. No water with power on, or contacts that won't close, points to the switch or the pump.

More Guides

Want a Pro to Take a Look?

Call or send the form with your town and what you're seeing.

  • Tell us your town and whether you have any water at all
  • Mention what you've noticed: clicking, sputtering, cloudy or smelly water
  • A local well pro calls back and confirms availability and exact pricing on a free quote

Call (845) 524-9364

Request Well Service

Fastest answer: call (845) 524-9364. We only use your details to respond to this request.

On a Private Well in Orange County?

No water, weak pressure, or a water test coming up for a sale — call and a local well pro confirms availability.

Call (845) 524-9364
Tap to call — a local well pro confirms availability(845) 524-9364